Complete the following steps to specify the gage linearity and bias study data.
- In Part
numbers, enter the column that contains the part names or numbers.
- In Reference
values, enter the column that contains the reference values for each part. The reference value is the known standard measurement for each part.
- In Measurement
data, enter the column that contains the observed measurements.
- (Optional) In Process
variation, enter a value that represents 6 * the process standard deviation, if you have it. You can either enter the process standard deviation from the Total Variation row of the Study Var (6 * SD) column of the output from a gage R&R study, or you can enter a known value (6 * the historical standard deviation).
In this worksheet, Part contains the part number identifiers, Reference contains the known standard measurement, and Response contains the measurement of each part.
C1 |
C2 |
C3 |
Part |
Reference |
Response |
1 |
2 |
2.7 |
1 |
2 |
2.5 |
1 |
2 |
2.4 |
2 |
2 |
2.5 |