Store statistics for Evaluate Measurement Process (EMP Crossed)

Stat > Quality Tools > Gage Study > Evaluate Measurement Process (EMP Crossed) > Storage

You can save statistics from your analysis to the worksheet so that you can use them in other analyses, graphs, and macros. Minitab stores the selected statistics after the last column of data. If you store the same statistic multiple times in the same worksheet, the analysis adds an underscore and a number to the column title. The number begins at 1 and increases each time you store the statistic.

For more details on any of these statistics, go to All statistics and graphs.

Variance components
Stores the variance components in the column Variance.
Percent contributions
Stores the percent of the total variation for the variance components in the column PTotal.
Standard deviations
Stores the standard deviation for the variance components in the column StdDev.
Each variance component is in a different row of the storage column. The components are in the following rows, which is the same order as the Variance Components table in the results:
Row 1
Test-retest error (Repeatability)
Row 2
Operator (Reproducibility)
Row 3
Part (Product variation)
Row 4
Total