Store statistics for Nonnormal Capability Analysis for Multiple Variables

Stat > Quality Tools > Capability Analysis > Multiple Variables (Nonnormal) > Storage

You can save statistics from your analysis to the worksheet so that you can use them in other analyses, graphs, and macros. Minitab stores the selected statistics after the last column of data. The names of the storage columns end with a number that increases as you store the same statistic multiple times.

The statistics that are available for storage depend on the options that you select for the analysis. The names of capability statistics depend on the naming convention that you select. With the AIAG/VDA naming convention, the names of overall capability statistics also depend on the process stage and calculation method. For more information, go to Capability index naming convention.

For more details on any of these statistics, go to All statistics and graphs.

Process data statistics

Variable name
Store the name of the column of measurements used for the analysis. Minitab stores the information in the column VarName1.
LSL
Store the lower specification limit. Minitab stores the value in the column LSL1.
Target
Store the target of the process. Minitab stores the value in the column Target1.
USL
Store the upper specification limit. Minitab stores the value in the column USL1.
Mean
Store the process mean. Minitab stores the value in the column Mean1.
Sample N
Store the sample size used for the analysis. Minitab stores the value in the column SampleN1.
Location
Store the location parameter of the distribution used for the analysis. Minitab stores the value in the column Location1.
Shape
Store the shape parameter of the distribution used for the analysis. Minitab stores the value in the column Shape1.
Scale
Store the scale parameter of the distribution used for the analysis. Minitab stores the value in the column Scale1.
Threshold
Store the threshold parameter of the distribution used for the analysis. Minitab stores the value in the column Threshold1.

Overall capability statistics

The names of capability statistics that use the overall variation depend on the naming convention. With AIAG/VDA naming, the names also depend on the process stage and calculation method.

For the Z-score method, Minitab uses the following names.

Statistic Six Sigma AIAG/VDA process performance AIAG/VDA process capability AIAG/VDA machine performance
Capability based on both specification limits Pp or Z.Bench Pp.Z or Zp.Bench Cp.Z or CZp.Bench Pm.Z or Zm.Bench
Capability for the lower specification limit PPL or Z.LSL PpL.Z or Zp.LSL CpL.Z or CZp.LSL PmL.Z or Zm.LSL
Capability for the upper specification limit PPU or Z.USL PpU.Z or Zp.USL CpU.Z or CZp.USL PmU.Z or Zm.USL
Capability for the specification limit closest to the process mean Ppk Ppk.Z Cpk.Z Pmk.Z

For the ISO method (geometric), Minitab uses the following AIAG/VDA names.

Statistic AIAG/VDA process performance AIAG/VDA process capability AIAG/VDA machine performance
Capability based on both specification limits Pp.G or Zp.Bench Cp.G or CZp.Bench Pm.G or Zm.Bench
Capability for the lower specification limit PpL.G or Zp.LSL CpL.G or CZp.LSL PmL.G or Zm.LSL
Capability for the upper specification limit PpU.G or Zp.USL CpU.G or CZp.USL PmU.G or Zm.USL
Capability for the specification limit closest to the process mean Ppk.G Cpk.G Pmk.G

Observed performance statistics

PPM or % < LSL
Store the observed parts per million (or observed percentage) less than the lower specification limit. Minitab stores the value in the column <LSL1.
PPM or % > USL
Store the observed parts per million (or observed percentage) greater than the upper specification limit. Minitab stores the value in the column >USL1.
PPM or % Total
Store the observed parts per million (or observed percentage) outside of the specification limits. Minitab stores the value in the column Total1.

Expected "overall" performance statistics

PPM or % < LSL
Store the expected parts per million (or the expected percentage) less than the lower specification limit, based on the overall variation. Minitab stores the value in the column O<LSL1.
PPM or % > USL
Store the expected parts per million (or the expected percentage) greater than the upper specification limit, based on the overall variation. Minitab stores the value in the column O>USL1.
PPM or % Total
Store the expected parts per million (or the expected percentage) outside the specification limits, based on the overall variation. Minitab stores the value in the column OTotal1.