Enter your data for Analyze Definitive Screening Design

Stat > DOE > Screening > Analyze Screening Design

In Responses, enter the columns of numeric data that you want to explain or predict with the factors. If you enter more than one response, Minitab fits a separate model for each response. The response is also called the Y variable.

In this worksheet, Power is the response and contains the strength values. The data has the following factors:
  • Train
  • Degas
  • Burst
  • Quiet
  • Center
  • Bandwidth
  • Sweep
C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12
StdOrder RunOrder PtType Blocks Train Degas Burst Quiet Center Bandwidth Sweep Power
12 1 2 1 0.10 0.10 10.0 10.0 10 5 0 599.0
9 2 2 1 1.00 0.10 1.0 10.0 5 10 0 661.9
4 3 2 1 0.10 0.55 1.0 10.0 0 10 10 627.7
2 4 2 1 0.55 0.10 1.0 1.0 0 0 0 722.6
17 5 0 1 0.55 0.55 5.5 5.5 5 5 5 603.8
8 6 2 1 0.10 0.10 1.0 5.5 10 0 10 543.1
7 7 2 1 1.00 1.00 10.0 5.5 0 10 0 698.4
15 8 1 1 1.00 0.10 10.0 10.0 0 0 10 671.6